Miscellaneous Parameters - Veikong gpd 515/g5 Startup Manual

Simplified startup procedure
Table of Contents

Advertisement

5.25
LOCAL/REMOTE AND REFERENCE SELECTION
M o d e 4
The final consideration for multiple frequency
command configuration modes is that any
combination of reference values may be configured
for operation. As an example, if only three speed
references are required, then the following example
will work.
b 1 - 0 1 = local operation;
H 1 - 0 3 = frequency select 1 at terminal 5;
H 1 - 0 4 = frequency select 2 at terminal 6;
H 3 - 0 5 = manual reference at terminal 16.
2-WIRE CONTROL
b 1 - 0 1 = 0
H 1 - 0 3 = 3
H 1 - 0 4 = 5
H 3 - 0 5 = 0
Freq.
Ref.
8
d1-01
0
Manual
0
(Multi-func.)
d1-03
0
5.26

MISCELLANEOUS PARAMETERS

o 2 - 0 1 : LOCAL/REMOTE Key Selection
This parameter determines if the LOCAL/REMOTE key is operative.
Setting
External Terminal
7
6
5
0
0
0
0
0
1
0
1
0
0
Disabled
1
Enabled
Continued
Factory setting: 1
Range: 0 or 1
Description
5-44
GPD 515/G5
5 ( H1-03 )
6 ( H1-04 )

Hide quick links:

Advertisement