NAME
NAME
DRIVE
Lights when the drive is in the Drive mode of operation.
FWD
Lights when Forward motor run has been selected.
REV
Lights when Reverse motor run has been selected.
REMOTE
Lights when the drive is programmed to operate from external RUN and STOP
SEQ
signals.
REMOTE
Lights when the drive is programmed to operate by an external frequency
REF
reference signal.
RUN
Off when drive is in stopped condition; lights steadily when Run signal is
active; blinks after Stop signal has been received and drive output is ramping
down. (See Figure 4-2.)
STOP
Lights steadily at initial power-up; blinks after Run signal becomes active but
frequency reference is zero; off when drive output is controlling motor speed.
(See Figure 4-2.)
NAME
LABEL
LOCAL
Pressing this key toggles between the Local (Digital Operator) and Remote (Termin-
REMOTE
als) modes of operation. Active only when the drive is in stopped condition.
JOG
IN DRIVE MODE: Pressing and holding this key will initiate Jog function: drive
output goes to programmed Jog Frequency ( d1-09 ) to check motor operation, or
to position machine. When key is released, output returns to zero and motor stops.
If the motor is already running, pressing this key will have no effect.
FWD
IN DRIVE MODE: Each press of this key will toggle between Forward and Reverse
REV
motor run direction. The selected direction is indicated by the FWD or REV lamp
being lit. If the selection is made while the drive is stopped, it determines the
direction the motor will run when started. If the selection is changed during running,
the drive will ramp the motor to zero speed and then ramp it up to set speed in
the opposite (i.e. newly selected) direction.
RUN
IN DRIVE MODE: If the drive is not programmed to operate by external RUN
and STOP signals (as indicated by REMOTE SEQ lamp being lit), pressing this key
will produce a Run command to initiate drive output to the motor. However,
output frequency will be zero if the frequency reference is zero at the time this key
is pressed.
STOP
IN DRIVE MODE: Pressing this key will produce a Stop command. The drive
will decelerate the motor in the programmed stopping manner, then drive output
will be disconnected from the motor.
T a b l e 4 - 1 . D i g i t a l O p e r a t o r C o n t r o l s
A. INDICATOR LAMPS
A. INDICATOR LAMPS
FUNCTION
FUNCTION
B. KEYPAD KEYS
B. KEYPAD KEYS
FUNCTION
FUNCTION
NOTE: Disabled if the drive is programmed
to use an external JOG input.