C3-04 - Veikong gpd 515/g5 Startup Manual

Simplified startup procedure
Table of Contents

Advertisement

T a b l e A 1 - 3 . D r i v e C X - X X P a r a m e t e r s – C o n t i n u e d
PARAMETER
F U N C T I O N
NUMBER
N A M E
C3-01
Slip
Compensation
Gain
C3-02
Slip
Compensation
Primary Delay
Time
C3-03
Slip
Compensation
Limit

C3-04

Slip
Compensation
Selection
During
Regeneration
C3-05
Flux Select
C3-06
Output Voltage 0 : Disabled - Output voltage
Limit
C4-01
Torque
Compensation
Gain
C4-02
Torque
Compensation
Time Constant
C4-03
Forward Torque
Compensation
At Start
C4-04
Reverse Torque
Compensation
At Start
C4-05
Torque
Compensation
At Start Time
Constant
D E S C R I P T I O N
0 : Disabled
1 : Enabled
0 : Slip Included - Flux is
calculated after slip
compensation is applied
1 : Slip Excluded - Flux is
calculated before slip
compensation is applied
limit and slip compensation
are disabled above base
speed
1 : Enabled - Output voltage
limit and slip compensation
are enabled above base
speed
INCRE-
S E T T I N G
M E N T
RANGE
0.1
0.0 - 2.5
1 ms
0 - 10000
1 %
0 - 250
1
0, 1
1
0, 1
1
0, 1
0.01
0.00 - 2.50
1 ms
0 - 10000
0.1%
0.0 - 200.0
0.1%
-200.0 - 0.0
1 ms
0 - 200
A1-7
A C C E S S L E V E L
F A C T O R Y
( S e e N o t e 3 )
S E T T I N G
0
1
2
(See Note 1)
B — B B
(See Note 1)
A — A —
200
A — A —
0
A A
A —
0
— — A —
0
— — A A
1.00
B B
B —
(See Note 1)
A A
A —
0.0
— — A —
0.0
— — A —
10
— — A —
P A R A .
REF .
3
5.38
5.38
5.38
5.38
5.38
5.38
5.42
5.42
5.42
5.42
5.42

Hide quick links: