Veikong gpd 515/g5 Startup Manual page 54

Simplified startup procedure
Table of Contents

Advertisement

2 . 2 b
( c o n t i n u e d )
DESCRIPTION
When all of the parameters
are entered, execute Auto-
Tuning.
The drive will first output
current to the motor, then run
the motor at a high speed.
During tuning, the following
message will appear:
If no problems are encountered,
the following message will
appear:
• If a problem occurs during
Auto-Tuning execution, see
section 6.2, AUTO TUNING
FAULTS & CORRECTIVE
ACTIONS .
Proceed to section 2.5,
"TEST RUN USING DIGITAL
OPERATOR"
KEY SEQUENCE
Press
twice
DATA
ENTER
Set the correct Nameplate voltage of the motor,
using:
Write the value to memory by pressing
DATA
ENTER
Enter the current and the rest of the parameters
following a similar procedure to that of the motor
nameplate voltage.
Press
Press
RUN
2-10
DIGITAL OPERATOR DISPLAY
Rated Voltage
Rated Voltage
RESET
Entry Accepted
briefly, then
Rated Voltage
Tuning Ready ?
Press RUN key
Tune Proceeding
XX HZ
Tune Successful
Tune Aborted
400.0 VAC
460.0 VAC
460.0 VAC
X.XX A
"Reason"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents