Veikong gpd 515/g5 Startup Manual page 59

Simplified startup procedure
Table of Contents

Advertisement

2 . 2 d
( c o n t i n u e d )
DESCRIPTION
Set parameter access level to
Advanced. This allows all
parameters to be viewed and
modified.
Set PG Pulses/Rev to the
correct value. (NOTE: For a
Yaskawa vector motor, the
correct value is 1024.)
KEY SEQUENCE
Press
, then
MENU
Press
, then
DATA
ENTER
Press
, then set drive to Advanced
DATA
using:
ENTER
Write value to memory by pressing:
DATA
ENTER
Press
, then
MENU
Press
, then
DATA
ENTER
Press
3 times
DATA
ENTER
Set the correct PPR, using:
Write value to memory by pressing:
DATA
ENTER
2-15
DIGITAL OPERATOR DISPLAY
** Main Menu **
Access Level
A1-01=
Advanced Level
Entry Accepted
briefly, then
Access Level
Advanced Level
twice
** Main Menu **
Programming
4 times
PG Pulses/Rev
PG Pulses/Rev
RESET
Entry Accepted
briefly, then
PG Pulses/Rev
F1-01=
Initialize
Quick Start
4
Group F
Options
00600
01024
1024

Hide quick links: