T a b l e A 1 - 1 0 . D r i v e U X - X X P a r a m e t e r s – C o n t i n u e d
PARAMETER
M O N I T O R I T E M
NUMBER
U2-06
Motor Speed
U2-07
Output Voltage
U2-08
DC Bus Voltage
U2-09
Output kWatts
U2-10
Torque
Reference
U2-11
Input Terminal
Status
U2-12
Output Terminal
Status
U2-13
Inverter Status
U2-14
Elapsed Time
U3-01
Last Fault
U3-02
Fault
Message 2
D E S C R I P T I O N
At time of most recent fault
At time of most recent fault
At time of most recent fault
At time of most recent fault
At time of most recent fault
At time of most recent fault
1 1 1 1 1 1 1 1
Control circuit terminal 1 : "Closed"
Control circuit terminal 2 : "Closed"
Control circuit terminal 3 : "Closed"
Control circuit terminal 4 : "Closed"
Control circuit terminal 5 : "Closed"
Control circuit terminal 6 : "Closed"
Control circuit terminal 7 : "Closed"
Control circuit terminal 8 : "Closed"
At time of most recent fault
10000111
Control circuit terminals 9-10 : "Closed"
Control circuit terminal 25 : "Closed"
Control circuit terminal 26 : "Closed"
Not Used
Not Used
Not Used
Not Used
Fault contact output active
At time of most recent fault
11111111
During run
During zero-speed
During reverse run
During reset signal input
During speed agree
Drive operation ready
Minor fault
Major fault
At time of most recent fault
Most recent fault
2nd most recent fault
D I S P L A Y
U N I T
0.01 Hz
0.1 V
1 V
0.1 kW
0.1 %
1 hour
A1-30
A C C E S S L E V E L
A N A L O G M O N I T O R
( S e e N o t e 3 )
O U T P U T L E V E L
0
1
O O O O
O O O O
O O O O
O O O O
— — — O
O O O O
O O O O
O O O O
O O O O
O O O O
O O O O
2
3