Veikong gpd 515/g5 Startup Manual page 69

Simplified startup procedure
Table of Contents

Advertisement

T a b l e 2 - 5 . T e s t R u n W i t h D i g i t a l O p e r a t o r - C o n t i n u e d
DESCRIPTION
Set a run frequency of 15 Hz.
Display the output frequency.
Run the motor in the forward
direction.
Run the motor in the reverse
direction.
KEY SEQUENCE
Press
DATA
ENTER
Set the frequency to 15 using:
Write the value to memory by pressing
DATA
ENTER
Press
, then
ESC
Press
RUN
Press
FWD
REV
2-25
DIGITAL OPERATOR DISPLAY
Frequency Ref
Frequency Ref
RESET
Entry Accepted
briefly, then
Frequency Ref
Output Freq
U1-02=
RUN light comes on and motor
ramps up to speed.
Output Freq
U1-02= 15.00 HZ
NOTE: Output frequency may be
slightly higher than the
frequency reference,
depending on the control
method selected.
RUN light remains on. FWD light
goes out and REV light comes on.
The motor ramps down to zero
speed, then ramps up in the
opposite direction.
Output Freq
U1-02= -15.00 HZ
NOTE: output frequency may be
slightly higher than the
frequency reference,
depending on the control
method selected.
000.00 HZ
015.00 HZ
015.00 HZ
0.00 HZ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents