Veikong gpd 515/g5 Startup Manual page 286

Simplified startup procedure
Table of Contents

Advertisement

R e m o t e M o u n t R e s i s t o r U n i t I n s t a l l a t i o n ( f o r G P D 5 1 5 C - A 0 0 3 t h r u - A 0 3 3
[ C I M R - G 5 M 2 0 P 4 1 F t h r u 2 7 P 5 1 F ] , - B 0 0 1 t h r u - B 0 3 4 [ 4 0 P 4 1 F t h r u 4 0 1 5 1 F ] ,
C 0 0 3 t h r u C 0 3 2 [ 5 1 P 5 1 F t h r u 5 0 2 2 1 F ] )
Since the Remote Mount Resistor Unit generates heat during dynamic braking
operation, install it in a location away from other equipment.
1 . Attach the Remote Mount Resistor Unit, maintaining a minimum 1.97 inch (50 mm)
clearance on each side and a minimum 7.87 inch (200 mm) clearance on top.
2 . Remove the Remote Mount
Resistor Unit cover to access
its terminal block. Connect
the Remote Mount Resistor
Unit to the drive and to
external control circuitry
according to the chart at right
and Figure A6-3.
3 . Reinstall and
secure
Remote
Mount Resistor
Unit cover and
drive front
cover.
4 . Proceed to
"ADJUSTMENTS"
on page A6-8.
-B001 thru -B034 [40P41F thru 40151F], and -C003 thru -C032 [51P51F thru 50221F])
IMPORTANT
CB
1M
L1 (R)
L1
1M
L2 (S)
L2
1M
L3 (T)
L3
PART OF USER SUPPLIED
EXTERNAL CIRCUIT
POWER
POWER
ON
THRX
OFF
1M
FAULT
CONTACT
Figure A6-3. Wiring Remote Mount Resistor Unit to Drive
(GPD515C-A003 thru -A033 [CIMR-G5M20P41F thru 27P51F],
Terminals
Lead Size (AWG)
Lead Type
Terminal Screw
* Power leads for the Remote Mount Resistor Unit generate high levels of
electrical noise; these signal leads must be grouped separately.
T1 (U)
GPD 515/G5
T2 (V)
T3 (W)
CONTROL
PCB
3
11
B1
B2
THRX
THRX
1M
A6-4
B, P
1, 2 *
12-10
18-14 *
600V ethylene propylene
rubber insulated, or equivalent
M4
T1
T2
T3
P
2
REMOTE
MOUNT
THG
RESISTOR
1
UNIT
B