5 . 3 2
M U L T I - F U N C T I O N INPUT TERMINALS ( T e r m . 3 - 8 )
H 1 - 0 1 : Terminal 3 Function
H 1 - 0 2 : Terminal 4 Function
H 1 - 0 3 : Terminal 5 Function
H 1 - 0 4 : Terminal 6 Function
H 1 - 0 5 : Terminal 7 Function
H 1 - 0 6 : Terminal 8 Function
These six parameters select the input signal
functions for terminals 3 thru 8, and can be
independently set.
Parameter settings are checked whenever
power is applied to the drive, or upon
exiting Program mode. A parameter set
value failure ( oPE3 ) will occur if any of
the following conditions are detected among
these six parameters:
(1)
Two or more of the parameters contain the same value (except for External
Fault, data " 2X ").
(2)
Two or three Speed Search functions (data " 61 ", " 62 ", or " 64 ") have
been selected.
(3)
Any Speed Search function (data " 61 ", " 62 ", or " 64 ") has been entered
into any parameter other than H 1 - 0 6 .
(4)
Both the Sample/Hold (data " A ") and Up/Down (data " 10 " & " 11 ")
functions have been selected.
(5)
The Up function (data " 10 ") and the Down function (data " 11 ") have
not both been selected.
(6)
The Trim Control Increase (Data "1C") AND Trim Control Decrease (Data "1D")
Functions have not both been selected.
Table 5-2 lists the possible data setting values for these parameters, with the function and
a brief description for each one.
For a few of the data settings, a more detailed description is given on the following pages;
for others, the description is given in other PROGRAMMABLE FEATURES paragraphs.
Factory settings:
H 1 - 0 1
H 1 - 0 2
H 1 - 0 3
H 1 - 0 4
H 1 - 0 5
H 1 - 0 6
EXTERNAL
CONTACTS
5-58
2-Wire control 3-Wire control
24
24
14
14
3
4
6
8
GPD 515/G5
3 H1-01
4 H1-02
MULTI-
> FUNCTION
5 H1-03
INPUT
6 H1-04
7 H1-05
8 H1-06