5.30
MULTI-FUNCTION ANALOG INPUTS ( T e r m . 1 4 & 1 6 )
H3-05 = 10
H3-09 = 10
FWD
TORQUE
LIMIT
–10V
MULTI-FUNCTION ANALOG INPUT
H3-05 = 12
H3-09 = 12
REGEN
TORQUE
LIMIT
–10V
MULTI-FUNCTION ANALOG INPUT
H3-05 = 14
H3-09 = 14
TORQUE
COMPEN-
SATION
–10V
MULTI-FUNCTION ANALOG INPUT
H 3 - 1 2 : Analog Input Filter Time
Constant
This parameter adjusts the time it takes to process the analog input signal. The signal
that comes into the drive on terminals 13, 14 and 16 goes through an analog to digital
converter, and then to the control circuit. This filter time constant determines the time
between converting and processing.
For cases when there is noise on the analog signal, this time constant may be increased.
Extending the processing time can help prevent erratic performance of the drive.
100%
0%
0V
10V
100%
0%
0V
10V
100%
0%
0V
10V
–100%
H3-05 = 11
H3-09 = 11
REV
TORQUE
LIMIT
–10V
H3-05 = 13
H3-09 = 13
TORQUE
REFERENCE
–10V
H3-05 = 15
H3-09 = 15
TORQUE
LIMIT
–100%
Factory setting: 0 . 0 0
Range: 0.00 to 2.00 seconds
5-56
Continued
100%
0%
0V
MULTI-FUNCTION ANALOG INPUT
100%
0%
0V
–100%
MULTI-FUNCTION ANALOG INPUT
100%
0%
0V
10V
MULTI-FUNCTION ANALOG INPUT
10V
10V