Veikong gpd 515/g5 Startup Manual page 66

Simplified startup procedure
Table of Contents

Advertisement

2 . 4
( c o n t i n u e d )
DESCRIPTION
Enter the motor rated full load
amps ( E2-01 ). This value can
be obtained from the motor
nameplate (motor full load
amps).
Enter the motor rated slip
( E2-02 ). This value can be
calculated using the following
formula:
(Ns - Nr)
E2-02 =
x 60 x 0.7
Ns
Nr = nameplate rated speed
Ns = synchronous speed
Ns = f
x 120 / # of motor poles
R
KEY SEQUENCE
Press
, then
ESC
Press
twice
DATA
ENTER
Set the FLA using:
Write value to memory by pressing
Press
, then
Set motor rated slip using:
Write value to memory by pressing
2-22
DIGITAL OPERATOR DISPLAY
RESET
DATA
ENTER
DATA
ENTER
RESET
DATA
ENTER
Function E2
Motor Setup
Motor Rated FLA
001.00 A
Motor Rated FLA
001.20 A
Entry Accepted
briefly, then
Motor Rated FLA
E2-01=
1.20 A
Motor Rated Slip
02.90 HZ
Motor Rated Slip
1.08 HZ
Entry Accepted
briefly, then
Motor Rated Slip
E2-02=
1.08 Hz

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents