Veikong gpd 515/g5 Startup Manual page 147

Simplified startup procedure
Table of Contents

Advertisement

5 . 3 2
M U L T I - F U N C T I O N INPUT TERMINALS ( T e r m . 3 - 8 )
T a b l e 5 - 2 . H 1 - 0 1 t h r u H 1 - 0 6 D a t a S e t t i n g s - C o n t i n u e d
DATA
FUNCTION
DATA
FUNCTION
20
External fault
t h r u
2F
30
PID integral reset
31
PID Integral Hold
60
DC injection braking
command
61
Speed Search 1
62
Speed Search 2
63
Energy saving operation
64
Speed Search 3
65
Kinetic energy braking
ride-thru NC
66
Kinetic energy braking
ride-thru NO
71
Speed / torque control
selection
72
Zero-Servo command
77
ASR gain selection
NOTES:
*
All contact closures must be maintained, except for speed search (Data " 61 ",
" 62", & ' 64 "), which may be momentary (see paragraph 5.32 D).
1.
Column headings refer to set value of A 1 - 0 2 , Control Method;
1 = V/f w/PG, 2 = Open loop vector, 3 = Flux vector.
DESCRIPTION
Signal Levels: 0 = state; 1 = pulse
DESCRIPTION
Second digit of setting is a hexadecimal value
which defines what type of external contact is
used and how the drive will react when the
signal input is active. S e e p a r a g r a p h 5 . 1 7
Closed = Set calculated integral time
value to 0. S e e p a r a g r a p h 5 . 3 6 F
Closed = Hold integrator at its present level
(PID Control). S e e p a r a g r a p h 5 . 3 6 F
Closed = DC injection braking active
S e e p a r a g r a p h 5 . 1 0 D
Closed * = Speed Search operation from
maximum frequency
S e e D a t a d e s c r i p t i o n f o l l o w i n g t h i s t a b l e
Closed * = Speed Search operation from set
frequency
S e e D a t a d e s c r i p t i o n f o l l o w i n g t h i s t a b l e
Closed = Energy saving
S e e p a r a g r a p h 5 . 1 6
Closed * = Speed Search operation from
output frequency
S e e D a t a d e s c r i p t i o n f o l l o w i n g t h i s t a b l e
Closed = KEB ride-thru is disabled
Closed = KEB ride-thru is enabled
Open = Speed control operation
Closed = Torque control operation
S e e p a r a g r a p h 5 . 4 3
Open = Zero-Servo OFF
Closed = Zero-Servo ON
S e e p a r a g r a p h 5 . 4 9 A
Closed = ASR proportional gain is set
according to C 5 - 0 3
5-61
Continued
AVAILABILITY
(See Note 1)
0
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0 = V/f,
2
3
X
X
X
X
X
X
X
X
X

Hide quick links: