Configuring The Service Loopback Eth-Trunk Interface; Configuring An Ipv6 Over Ipv4 Manual Tunnel - Huawei S9300 Configuration Manual

Terabit routing switch
Table of Contents

Advertisement

S9300&S9300E Terabit Routing Switch
Configuration Guide - IP Service
No.
4
5

11.4.2 Configuring the Service Loopback Eth-Trunk Interface

Context
Before enabling the service loopback function on an Eth-Trunk interface, note the following:
l
l
Do as follows on the S9300&S9300E.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface eth-trunk trunk-id
The Eth-Trunk interface view is displayed.
Step 3 Run:
service type tunnel
The Eth-Trunk interface is enabled with the service loopback function.
Step 4 Run:
quit
Return to the system view.
Step 5 Run:
interface interface-type interface-number
The interface view is displayed.
Step 6 Run:
eth-trunk trunk-id
The interface is added to the Eth-Trunk.
----End

11.4.3 Configuring an IPv6 over IPv4 Manual Tunnel

A manual IPv6 over IPv4 tunnel is a P2P tunnel. The source address and destination address of
a manual IPv6 over IPv4 tunnel are both manually assigned. The source address and destination
Issue 01 (2012-03-15)
Data
Destination IPv4 address of the tunnel
Authentication word of the GRE tunnel (only for the GRE tunnel)
Before enabling the service loopback function, create an Eth-Trunk, add member interfaces
to the Eth-Trunk and keep it in the Up state.
Only one interface enabled with the service loopback function is needed on a device.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.