3. DISPLAY AND OPERATION SECTIONS

3.1.6 Parameter mode

(1) Parameter mode transition
After selecting the corresponding parameter mode with the "MODE" button, pressing the "UP" or
"DOWN" button changes the display as shown below.
From alarm mode
To status display mode
Basic setting
Gain/filter
parameters
parameters
[Pr. PA01]
[Pr. PB01]
[Pr. PA02]
[Pr. PB02]
[Pr. PA31]
[Pr. PB63]
[Pr. PA32]
[Pr. PB64]
(2) Operation method
(a) Parameters of 5 or less digits
The following example shows the operation procedure performed after power-on to change the
control mode to the positioning mode (point table method) with [Pr. PA01 Operation mode]. Press
"MODE" to switch to the basic setting parameter display.
To shift to the next parameter, press the "UP" or "DOWN" button.
After changing [Pr. PA01], cycle the power to enable the setting.
MODE
Extension setting
I/O setting
parameters
parameters
[Pr. PC01]
[Pr. PD01]
[Pr. PC02]
[Pr. PD02]
[Pr. PC79]
[Pr. PD47]
[Pr. PC80]
[Pr. PD48]
3 - 17
Extension setting 2
Extension setting 3
parameters
parameters
[Pr. PE01]
[Pr. PF01]
[Pr. PE02]
[Pr. PF02]
[Pr. PE63]
[Pr. PF47]
[Pr. PE64]
[Pr. PF48]
......
The parameter number is displayed.
Press "UP" or "DOWN" to change the number.
Press "SET" twice.
......
The set value of the specified parameter number blinks.
Press "UP" six times.
......
During blinking, the set value can be changed.
Use "UP" or "DOWN".
( _ _ _ 6: Positioning mode (point table method))
To decide the value , press "SET".
Positioning control
parameters
[Pr. PT01]
[Pr. PT02]
UP
DOWN
[Pr. PT47]
[Pr. PT48]