4. HOW TO USE THE POINT TABLE

4.6.2 Detailed setting window

The position data range and unit can be changed with the detailed setting in the point table window. For the
position data range and unit of [Pr. PT01] setting, refer to section 4.2.2. To reflect the setting for the
corresponding parameter, click "Update Project" in the point table window.
(1) Command method selection (PT01 *CTY): 1)
Select either the absolute position command method or the incremental value command method.
(2) Others
(a) Feed length multiplication parameter setting STM (PT03 *FTY): 2)
Select a feed length multiplication from 1/10/100/1000.
(b) Position data unit setting (PT01 *CTY): 3)
Select a unit of position data from mm/inch/degree/pulse. When degree or pulse is selected for the
unit, the setting of feed length multiplication will be disabled.