10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
(f) Auxiliary function
Writes auxiliary function of point tables.
Transmits the command [C] [B] + the data No. [0] [1] to [1] [F] corresponding to the point tables to
write. Refer to section 10.1.1.
When changing the auxiliary function frequently using communication, set "1" to the write mode to
change only the RAM data in the servo amplifier.
When changing data once or more within an hour, do not write it to the EEP-ROM.
(g) M code
Writes M code of point tables.
M code will be available in the future.
Transmits the command [C] [2] + the data No. [0] [1] to [1] [F] corresponding to the point tables to
write. Refer to section 10.1.1.
When changing the M code frequently using communication, set "1" to the write mode to change
only the RAM data in the servo amplifier.
When changing data once or more within an hour, do not write it to the EEP-ROM.
Command
Data No.
[C] [B]
[0] [1] to [1] [F]
0
Hexadecimal data
Writing mode
0: Writing to EEP-ROM/RAM
1: Writing to RAM
Command
Data No.
[C] [2]
[0] [1] to [1] [F]
0
Hexadecimal data
Writing mode
0: Writing to EEP-ROM/RAM
1: Writing to RAM
10 - 31
Data
Refer to the following:
Data
Refer to the following: