7. PARAMETERS
No./symbol/
Setting
name
digit
PC14
_ _ x x
MOD1
Analog
monitor 1
output
_ x _ _ For manufacturer setting
x _ _ _
PC15
_ _ x x
MOD2
Analog
monitor 2
output
_ x _ _ For manufacturer setting
x _ _ _
PC16
MBR
Electromagne
tic brake
sequence
output
PC17
ZSP
Zero speed
Analog monitor 1 output selection
Select a signal to output to MO1 (Analog monitor 1). Refer to app. 8.3 of "MR-JE-_A
Servo Amplifier Instruction Manual" for detection point of output selection.
Refer to table 7.8 or 7.9 for settings.
Table 7.8 Analog monitor setting value
Setting
value
_ _ 0 0 Servo motor speed (±8 V/max. speed) (Note 1)
_ _ 0 1 Torque (±8 V/max. torque) (Note 3)
_ _ 0 2 Servo motor speed (+8 V/max. speed) (Note 1)
_ _ 0 3 Torque (+8 V/max. torque) (Note 3)
_ _ 0 4 Current command (±8 V/max. current command)
_ _ 0 5 Command pulse frequency (±10 V/±4 Mpulses/s)
_ _ 0 6 Servo motor-side droop pulses (±10 V/100 pulses) (Note 2)
_ _ 0 7 Servo motor-side droop pulses (±10 V/1000 pulses) (Note 2)
_ _ 0 8 Servo motor-side droop pulses (±10 V/10000 pulses) (Note 2)
_ _ 0 9 Servo motor-side droop pulses (±10 V/100000 pulses) (Note 2)
_ _ 0 D Bus voltage (+8 V/400 V)
_ _ 0 E Speed command 2 (±8 V/max. speed) (Note 1)
_ _ 1 7 Internal temperature of encoder (±10 V/±128 °C)
Note 1. The maximum speed of the HF-KN series servo motor is 4500 r/min and that of the HG-KN
series is 5000 r/min. Please watch out when using an HG-KN series servo motor as a
replacement for the HF-KN series servo motor because HG-KN series outputs 8 V at 5000
r/min. HG-KN series servo motors output 8 V at 6000 r/min when you set "_ _ _ 1" in [Pr. PA28]
to change the maximum speed to 6000 r/min.
2. Encoder pulse unit
3. The value in [Pr. PA11] or [Pr. PA12] whichever is higher is applied for the maximum torque.
Analog monitor 2 output selection
Select a signal to output to MO2 (Analog monitor 2). Refer to app. 8.3 of "MR-JE-_A
Servo Amplifier Instruction Manual" for detection point of output selection.
Refer to [Pr. PC14] for settings.
Set the delay time from when MBR (Electromagnetic brake interlock) turns off until
when the base drive circuit is shut-off.
Setting range: 0 to 1000
Set an output range of ZSP (Zero speed detection).
ZSP (Zero speed detection) has hysteresis of 20 r/min.
Setting range: 0 to 10000
Function
Item
7 - 39
Control
Initial
mode
value
[unit]
CP CL
00h
0h
0h
01h
0h
0h
0
[ms]
50