Interrupt Positioning Function - Mitsubishi MR-JE-200A Instruction Manual

Mr-je series general-purpose interface ac servo. positioning mode
Hide thumbs Also See for MR-JE-200A:
Table of Contents

Advertisement

6. APPLICATION OF FUNCTIONS

6.2.2 Interrupt positioning function

The interrupt positioning function executes an operation by changing the remaining distance to the travel
distance that is set with [Pr. PT31] (Mark sensor stop travel distance) when MSD (Mark detection) is turned
on. The interrupt positioning function is enabled by setting [Pr. PT26] to "1 _ _ _".
(1) Parameters
Set the parameters as follows:
Item
Control mode selection
Mark detection function selection
MSD (Mark detection) Polarity
selection
Mark sensor stop travel distance
(lower three digits)
Mark sensor stop travel distance
(upper three digits)
Mark detection range + (lower
three digits)
Mark detection range + (upper
three digits)
Mark detection range - (lower
three digits)
Mark detection range - (upper
three digits)
POINT
The interrupt positioning function can be used with the point table method and
the program method. However, the interrupt positioning function is disabled in
the following condition.
During home position return
During manual operation
During stop
During deceleration or stop with TSTP (Temporary stop/restart)
An error may occur depending on the droop pulses at the time of MSD (Mark
detection) is turned on and a minimum stopping distance required for
deceleration.
Parameter to be used
[Pr. PA01]
[Pr. PT26]
[Pr. PT29]
[Pr. PT30]
[Pr. PT31]
[Pr. PC66]
[Pr. PC67]
[Pr. PC68]
[Pr. PC69]
Select a control mode.
_ _ _ 6 (Positioning mode (point table method))
_ _ _ 7 (Positioning mode (program method))
Set the mark detection function selection as follows:
1 _ _ _: Interrupt positioning function
Starts the interrupt positioning function at rising of MSD (Mark
detection).
The polarity of MSD (Mark detection) can be changed with
[Pr. PT29].
Starts the interrupt positioning function at rising of MSD
(Mark detection) if "_ _ _ x" bit 3 of [Pr. PT29] is off.
Starts the interrupt positioning function at falling of MSD
(Mark detection) if "_ _ _ x" bit 3 of [Pr. PT29] is on.
Set the lower three digits of the travel distance after the mark
detection.
The travel distance starts from the current position regardless
of the setting of absolute value command method or
incremental value command method.
Set the upper three digits of the travel distance after the mark
detection.
The travel distance starts from the current position regardless
of the setting of absolute value command method or
incremental value command method.
Set the upper and lower limits of the interrupt positioning
function. If a sign for the upper and lower differ, [AL. 37]
occurs. When the roll feed display is enabled, set a valid
range with the travel distance from the starting position.
6 - 58
Setting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-je-40aMr-je-100a

Table of Contents