7. PARAMETERS

7.2.4 I/O setting parameters ([Pr. PD_ _ ])

No./symbol/
Setting
name
digit
PD01
Select input devices to turn on automatically.
*DIA1
_ _ _ x
Input signal
(HEX)
automatic on
selection 1
_ _ x _
(HEX)
_ x _ _
(HEX)
x _ _ _
(HEX)
_ _ _ x (BIN): For manufacturer setting
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): SON (Servo-on)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): For manufacturer setting
_ _ _ x (BIN): PC (Proportional control)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): TL (External torque limit selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
_ _ _ x (BIN): For manufacturer setting
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): LSP (Forward rotation stroke end)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): LSN (Reverse rotation stroke end)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ _ X (BIN): EM2 (Forced stop 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
Function
7 - 47
Control
Initial
mode
value
[unit]
CP CL
0h
0h
0h
0h