Mitsubishi MR-JE-200A Instruction Manual page 266

Mr-je series general-purpose interface ac servo. positioning mode
Hide thumbs Also See for MR-JE-200A:
Table of Contents

Advertisement

6. APPLICATION OF FUNCTIONS
(2) Reading data
(a) Rising latch data or falling latch data (data part)
Reads MSD (Mark detection) rising latch data or MSD (Mark detection) falling latch data.
1) Transmission
Transmit command [1] [A] and data No. [0] [0] or [0] [1] corresponding to the point tables to read.
Refer to section 10.1.1.
2) Return
The slave station returns the position data of point table requested.
(b) Rising latch data or falling latch data (data part + additional information)
Reads MSD (Mark detection) rising latch data or MSD (Mark detection) falling latch data.
1) Transmission
Transmit command [1] [A] and data No. [0] [2] or [0] [3] corresponding to the point tables to read.
Refer to section 10.1.1.
2) Return
The slave station returns the speed data of point table requested.
Data will be received in hexadecimal per set command.
Hexadecimal should be changed to decimal.
Example
Data "000186A0" will be 100.000 mm in the command-side unit.
A decimal point position depends on setting contents of [Pr. PT01] and [Pr. PT03].
Data will be received in hexadecimal per set command.
Hexadecimal should be changed to decimal.
Example
Data "000186A0" will be 100.000 mm in the command-side unit.
A decimal point position depends on setting contents of [Pr. PT01] and [Pr. PT03].
Display type
0: Data must be converted into decimal
1: Data is used unchanged in hexadecimal
Decimal point position
0: No decimal point
1: First least significant digit (not used normally)
2: Second least significant digit
3: Third least significant digit
4: Forth least significant digit
5: Fifth least significant digit
6 - 53