3. DISPLAY AND OPERATION SECTIONS

3.1.5 Point table setting

You can set the target position, servo motor speed, acceleration time constant, deceleration time constant,
dwell, auxiliary function and M code.
(1) Display transition
Point table transition
Point table No. 1
Point table No. 2
Point table No. 3
UP
DOWN
Point table No. 29
Point table No. 30
Point table No. 31
SET
MODE
3 - 13
Setting item transition
Target position
Servo motor speed
Acceleration time
constant
Deceleration time
constant
Dwell
Auxiliary function
M code
UP
DOWN