Parameter Mode - Mitsubishi melservo-j2 series Instruction Manual

Built-in positioning function servo amplifier
Hide thumbs Also See for melservo-j2 series:
Table of Contents

Advertisement

7. DISPLAY AND OPERATION

7.6 Parameter Mode

Change the parameter settings when:
• The regenerative brake option is used;
• The number of pulse per servo motor revolution is changed
• The machine mounted with the servo motor hunts or operational performance is further improved.
The parameter whose abbreviation is marked
changing its setting. (Refer to Section 5.2.1.)
(1) Operation example
1) 4-digit parameter
The following example shows the operation procedure performed after power-on to change the home
position setting method (Parameter No.8) into the data setting type.
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the parameter No.8 setting, change its set value, then switch power off once and
switch it on again to make the new value valid.
Press
four times. Select parameter No.8 with
MODE
The parameter number is displayed.
Press
or
to change the number.
UP
DOWN
Press
twice.
SET
The set value of the specified parameter number flickers.
Press
twice.
UP
During flickering, the set value can be changed.
Use
or
.
UP
DOWN
(!!!2: Data setting type)
Press
to enter.
SET
7 - 8
is made valid by switching power off, then on after
UP
or
.
DOWN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2-c

Table of Contents