10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)

10.2 Detailed explanations of commands

10.2.1 External I/O signal status (DIO diagnosis)

(1) Reading input device status
The current input device status can be read.
(a) Transmission
Transmit command [1] [2] + data No. [0] [0] to [0] [2].
(b) Return
The slave station returns the status of the input devices.
Command
Data No.
[1] [2]
[0] [0] to [0] [2]
b31
Command of each bit is transmitted to the master station as hexadecimal data.
Bit
Data No. [0] [0]
0
SON
1
LSP
2
LSN
3
TL
4
TL1
5
PC
6
RES
7
CR
8
SP1
9
SP2
10
SP3
11
ST1/RS2
12
ST2/RS1
13
CMX1
14
CMX2
15
LOP
16
17
18
EM2/EM1
19
20
STAB2
21
22
23
24
TSTP
25
26
27
CDP
28
29
30
31
10 - 14
Symbol
Data No. [0] [1]
MSD
PI1
PI2
PI3
CAMC
CI0
CI1
CI2
CI3
CLTC
CPCD
b1b0
1: On
0: Off
Data No. [0] [2]
MD0
TCH
TP0
TP1
OVR
DOG
LPS
DI0
DI1
DI2
DI3
DI4