4.10
Resource Programming
Description
Selection
Default
Programming
Conditions
Feature References

System Data Printout

Starts or stops printing of the system data. All the current system-
programmed data is printed out.
Start / Stop
Not applicable.
1.
Enter 802.
Display: System Data Dump
2.
Press NEXT.
Display: Print-Out:Start
3.
Press STORE to start printing.
Printing starts.
To stop printing in the middle of printing, press SELECT and go to
step 4.
When printing is completed, the display shows:
Display: Print-Out:Finish
4.
Press STORE.
Display: Print-Out:Stop
5.
Press END.
• It is necessary to connect a printer to the EIA (RS-232C) port provided
on the system.
• You may stop printing by pressing the END button, while records are
being printed out.
• You cannot restart the printout while records are being output.
Section 3, Features,
Station Message Detail Recording (SMDR)
System Programming
802
4-159