Note:
• The UCD Time Table is not available for incoming extensions or transferred calls.
• The overflow extension is the IRNA destination of the hunting group or the CO line
group assigned by program [134]–[135] "Hunting Intercept — Day / Night" or
[409]–[410] "Intercept Extension — Day / Night". If both of them are assigned, the
IRNA destination of the hunting group will be effective.
• If the overflow extension is not assigned, the system will not answer the call and
waits for an idle extension.
• If the Time Table number is not assigned, the system will not answer the call. In this
case, IRNA will be employed.
• In sequence assignment, "Sx" can be assigned to a space other than the first only
when another "Sx" is assigned in the first space.
• In sequence assignment, an assignment after "TR", "RT" or "Blank" is not available.
• If a timer is the first item in a Time Table sequence, it will delay answering
according to the Timer's setting. The caller will hear a ringback tone.
• Music on Hold after an OGM can be changed to a ringback tone by program [990]
"System Additional Information, Area 01 – Bit 1."
Conditions
3-184
Features
• UCD can be used in the following cases:
a) The floating number of UCD is assigned as the Direct In Lines
(DIL) 1:1 destination.
b) The floating number of UCD is assigned as the Intercept Routing
destination.
c) The floating number of UCD is dialled from an extension.
d) The floating number of UCD is assigned as the Direct Dialling In
(DDI) destination.
e) The floating number of UCD is assigned as the UCD Overflow
destination.
• This feature requires assigning an UCD group in System Programming.
An extension can belong to two or more UCD groups.
• The floating number can be assigned on a hunting group basis. The
UCD group is based on the hunting group.
• It is possible to set the log-in or log-out status on an extension basis.
An UCD call can be sent to an extension in log-in status within the
UCD group, but cannot be sent to extensions in log-out status. If the
extension would like to leave the group temporarily, the extension sets
the log-out status by the feature number to prevent UCD calls being
sent to his/her extension. When the extension re-joins the group, the
extension sets the log-in status.
• If all extensions are in log-out status, the system will not answer the
call. In this case, IRNA will be employed.