8.2.2 Site Planning
Precautions
Cell Station and office equipment such as a computer,
telex, fax, etc., or microwaves.
Cell Station and portable station
Two portable stations
Portable station and proprietary wired telephone
The system and Cell Station
Note
8-8
DECT Portable Station Section
• The Cell Station should be kept free of dust, moisture, high tem-
perature (more than 40˚C), low temperature (less than 5˚C),
vibration, and should not be exposed to direct sunlight.
• If a backup system for use during a Cell Station power failure is
required, set the system cable resistance within 20 Ω.
• Keep distance between the equipment listed below in order to
prevent noise, interference or the disconnection of a conversa-
tion.
E
QUIPMENT
• In Cell Station overlap areas, if the signal from one Cell Station
becomes weak, the DECT portable station will start call handover to
the next Cell Station. However if there is no free channel for a call
handover, the DECT portable station will remain with its current Cell
Station until out of range and the call is lost.
• Too many Cell Stations in a small area can cause problems due to con-
flicts over which signal channels each Cell Station can use.
Ideally Cell Stations should be a minimum of 25 to 40 meters apart.
D
ISTANCE
more than 1.8 meters
more than 1 meter
more than 0.5 meter
more than 1 meter
more than 2 meters