Site Survey; Site Survey Specification; Flow Chart Of The Site Survey - Panasonic KX-TD1232E Installation Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD1232E:
Table of Contents

Advertisement

8.2.5 Site Survey

8.2.5 Site Survey

Site Survey Specification

Flow Chart of the Site Survey

Check the Cell Station ID number.
Assign the Cell Station ID number to the PS.
Unplug the cable from the Cell Station.
Prepare the DIP-Switch of the Cell Station for
the Radio Signal Test mode.
Locate the Cell Station temporarily and con-
nect the AC power cord.
Survey the site using the PS.
Were the correct results obtained?
No
Disconnect the AC power cord, set the DIP-
Switch to the normal mode, and plug in the
cable.
8-18
DECT Portable Station Section
The KX-TD7500 portable station has Radio Signal Test Mode
which monitors the state of link as one of the means to determine
the site planning for the KX-TD142. In the mode, the frame loss
and signal strength of a synchronous slot, and the signal strength of
the other slots can be measured when the portable station is linking
with the KX-TD142.
Yes
(See pages 8-19 and 8-20.)
(See page 8-21.)
(See page 8-22.)
(See page 8-23.)
(See page 8-24.)
(See pages 25 through 27.)
(See page 8-28.)