:TRIGger:BLOCk:BRANch:EVENt

This command branches to a specified block when a specified trigger event occurs.
Type
Command only
Usage
:TRIGger:BLOCk:BRANch:EVENt <blockNumber>, <event>, <branchToBlock>
<blockNumber>
<event>
<branchToBlock>
Details
The branch-on-event block goes to a branching block after a specified trigger event occurs. If the
trigger event has not yet occurred when the trigger model reaches the branch-on-event block, the
trigger model continues to execute the blocks in the normal sequence. After the trigger event occurs,
the next time the trigger model reaches the branch-on-event block, it goes to the branching block.
If you set the branch event to none, an error is generated when you run the trigger model.
The following table s hows the cons tants for the events.
Trigger events
Event description
No trigger event
Front-panel TRIGGER key press
Notify trigger block <n> (1 to 8); the trigger model generates a
trigger event when it executes the notify block
A command interface trigger:
Any remote interface: *TRG
GPIB only: GET bus command
VXI-11: VXI-11 command device_trigger
Line edge (either rising, falling, or either based on the
configuration of the line) detected on digital input line <n> (1 to 6)
Line edge detected on TSP-Link synchronization line <n> (1 to 3)
Appropriate LXI trigger packet is received on LAN trigger object
<n> (1 to 8)
Trigger event blender <n> (1 or 2), which combines trigger events BLENder<n>
Trigger timer <n> (1 to 4) expired
Source limit condition occurs
6-190
Model 2461 Interactive SourceMeter® Instrument Reference Manual
Affected by
Recall settings
Instrument reset
Power cycle
The sequence of the block in the trigger model
The event that must occur before the trigger model branches the specified block
The block number of the trigger model block to execute when the specified event
occurs
Where saved
Save settings
Event constant
NONE
DISPlay
NOTify<n>
COMMand
DIGio<n>
TSPLink<n>
LAN<n>
TIMer<n>
SLIMit
Default value
Not applicable