Keithley 2461 Reference Manual page 297

1kw pulse mode interactive sourcemeter instrument
Table of Contents

Advertisement

Section 3: Functions and features
Using SCPI commands:
See the descriptions of the TRIGger:LOAD commands for details on the options available for each
predefined trigger model:
:TRIGger:LOAD "ConfigList"
:TRIGger:LOAD "DurationLoop"
:TRIGger:LOAD "Empty"
:TRIGger:LOAD "GradeBinning"
:TRIGger:LOAD "LogicTrigger"
:TRIGger:LOAD "LoopUntilEvent"
:TRIGger:LOAD "SimpleLoop"
:TRIGger:LOAD "SortBinning"
Using TSP commands:
See the descriptions of the trigger.model.load() command for details on the options available
for each predefined trigger model:
trigger.model.load() — ConfigList
trigger.model.load() — DurationLoop
trigger.model.load() — Empty
trigger.model.load() — GradeBinning
trigger.model.load() — LogicTrigger
trigger.model.load() — LoopUntilEvent
trigger.model.load() — SimpleLoop
trigger.model.load() — SortBinning
Using a predefined trigger model to develop a trigger model
The Model 2461 includes predefined trigger models that you can use as a starting point for
developing your trigger model.
After modifying a predefined trigger model, you can save it in a saved setup for future use. See
Saving setups
Using the front panel:
1. Press the MENU key.
2. Under Trigger, select Templates. The TRIGGER MODEL TEMPLATES screen is displayed.
3. Next to Templates, select the trigger model to use.
4. If the template you select has additional settings, you can use the default values or make any
necessary changes to the settings.
5. Select EXIT to return to the MENU screen.
6. Under Trigger, select Configure. The blocks for the predefined trigger model are displayed.
7. Choose or modify the blocks as needed. See
8. When the blocks are set up, select EXIT to return to the MENU screen.
9. Press the TRIGGER key to initiate the trigger model. The trigger mode indicator shows the status
of the trigger mode. See
3-126
(on page 6-222)
(on page 6-224)
(on page 6-225)
(on page 6-226)
(on page 6-228)
(on page 6-229)
(on page 6-231)
(on page 6-233)
(on page 8-260)
(on page 8-263)
(on page 2-137) for information on how to save a configuration.
Trigger mode indicator
Model 2461 Interactive SourceMeter® Instrument Reference Manual
(on page 8-261)
(on page 8-264)
(on page 8-266)
(on page 8-267)
(on page 8-270)
(on page 8-272)
Assembling trigger model blocks
(on page 2-16) for descriptions of the indicators.
(on page 3-127).