116-711 PLW form synthesis error

Synthesis is impossible because the size/orientation of the PLW form's drawing is different
from that of the paper.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Select the paper with the size and orientation of the registered form.
Status Indicator RAPs
116-711, 116-712
116-712 Insufficient PLW form capacity
The PLW form/logo data cannot be registered because of the insufficient RAM or Hard Disk
space.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Use the Operation Panel to check the registered forms/logos, and delete unnecessary ones.
Or increase the allocated capacity of the RAM disk.
02/03
2-492
Initial issue