Xerox DocuColor 2240 Service Manual page 917

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

Chain-Link
Name
742-059
Pre-T/A Start Timing TTM-Tray 3
742-060
Pre-T/A Start Timing TTM-Tray 4
742-062
Adjust Pre-Feed Position 3TM-Tray 2
742-063
Adjust Pre-Feed Position 3TM-Tray 3
742-064
Adjust Pre-Feed Position 3TM-Tray 4
742-065
Adjust Pre-Feed Position TTM-Tray 2
742-066
Adjust Pre-Feed Position TTM-Tray 3
742-067
Adjust Pre-Feed Position TTM-Tray 4
742-068
Adjust Pre-Feed Position 1TM-1
742-069
Main Feed Start Timing 3TM-Tray 2
742-070
Main Feed Start Timing 3TM-Tray 3
742-071
Main Feed Start Timing 3TM-Tray 4
742-072
Main Feed Start Timing TTM-Tray 2
742-073
Main Feed Start Timing TTM-Tray 3
742-074
Main Feed Start Timing TTM-Tray 4
742-076
Adjust Side Regi Tray 2
742-077
Adjust Side Regi Tray 3
742-078
Adjust Side Regi Tray 4
742-079
Adjust Side Regi Tray Module All
742-080
Paper remaining (calc) 3TM-Tray 2
742-081
Paper remaining (calc) 3TM-Tray 3
742-082
Paper remaining (calc) 3TM-Tray 4
742-083
Paper remaining (calc) TTM-Tray 2
742-084
Paper remaining (calc) TTM-Tray 3
742-085
Paper remaining (calc) TTM-Tray 4
742-087
OCT present
742-088
Dup On Timing (From Regi Start)
742-089
OCT Start Timing (Home)
742-090
OCT Start Timing (Home)
DC3535 only
742-093
Pre-T/A Start Timing 3TM-Tray 2
DC2240/1632
742-093
Pre-T/A Start Timing 3TM-Tray 2
DC3535
742-094
Pre-T/A Start Timing 3TM-Tray 3
DC2240/1632
Initial issue
DC 3535/2240/1632
Table 1 Chain 742
Default
Range
Description
74
0~115
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (457~957 msec.) (1bit=2.4462 msec.)
74
0~115
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (431~931 msec.) (1bit=2.4462 msec.)
0
0~40
Set time between Feed Out Sensor On and Feed Motor Off (0~400 msec (1bit=10 msec.)
0
0~40
Set time between Feed Out Sensor On and Feed Motor Off (0~400 msec.). (1bit=10 msec.)
0
0~40
Set time between Feed Out Sensor On and Feed Motor Off (0~400 msec.). (1bit=10 msec.)
0
0~40
Set time between Feed Out Sensor On and Feed Motor Off (0~400 msec.). (1bit=10 msec.)
0
0~40
Set time between Feed Out Sensor On and Feed Motor Off (0~400 msec.). (1bit=10 msec.)
37
10~50
Set time between Feed Out Sensor On and Feed Motor Off (100~500 msec.). (1bit=10 msec.) Default=370ms
0
0~40
Set time between Feed Out Sensor On and Feed Motor Off (0~400 msec.). (1bit=10 msec.)
20
0~44
Set time between Main Feed Start and the Pre-T/A (330~830 msec.). (1bit=10 msec.)
20
0~44
Sets time between Main Feed Start and Pre-T/A (570~1070 msec.). (1bit=10 msec.)
20
0~44
Sets time between Main Feed Start and Pre-T/A (810~1310 msec.). (1bit=10 msec.)
20
0~44
Sets time between Main Feed Start and Pre-T/A (330~830 msec.). (1bit=10 msec.)
20
0~44
Sets time between Main Feed Start and Pre-T/A (780~1280 msec.). (1bit=10 msec.)
20
0~44
Sets time between Main Feed Start and Pre-T/A (1410~1910 msec.). (1bit=10 msec.)
20
0~50
Side Regi adjustment of Tray 2 (1bit=0.211mm)
20
0~50
Side Regi adjustment of Tray 3 (1bit=0.211mm)
20
0~50
Side Regi adjustment votary 4 (1bit=0.211mm)
25
0~50
Side Regi adjustment of Trays 2, 3, 4 (Batch adjustment) (1bit=0.211mm)
0
0~4000
Saves the cumulative Lift-up time from Tray insertion (Calculation of remaining paper level detected).
0
0~4000
Saves the cumulative Lift-up time from Tray insertion (Calculation of remaining paper level detected).
0
0~4000
Saves the cumulative Lift-up time from Tray insertion (Calculation of remaining paper level detected).
0
0~4000
Saves the cumulative Lift-up time from Tray insertion (Calculation of remaining paper level detected).
0
0~12000
Saves the cumulative Lift-up time from Tray insertion (Calculation of remaining paper level detected).
0
0~15000
Saves the cumulative Lift-up time from Tray insertion (Calculation of remaining paper level detected).
1
0~1
0=Not available; 1=Available
20
0~40
Synchronize adjustment to be same as the Regi Clutch at Regi Start (Double Speed)
DC2240/1632: (1bit=1.31136 msec.)
DC3535: (1bit=1.5418 msec.)
17
0~112
OCT (Home) Start Timing Adjustment (Double Speed)
DC2240/1632: (1bit=1.31136 msec.)
DC3535: (1bit=1.5418 msec.)
17
0~112
OCT (Home) Start Timing Adjustment (Heavy 1) (1bit=2.4462 msec.)
139
0~215
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (303~803 msec.) (1bit=1.31136 msec.)
118
0~183
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (303~803 msec.) (1bit=1.5418 msec.)
139
0~215
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (365~865 msec.) (1bit=1.31136 msec.)
02/03
6-25
General Procedures and Information
742--xxx Paper Handling NVM List

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 3535Docucolor 1632

Table of Contents