Table 2 Output Component Control Codes
Code
Name
Description
009-002
#M_Disp MOT
M Color Disp. MOT turns ON, and switches
OFF automatically after 5sec.
009-003
#C_Disp MOT
C Color Disp. MOT turns ON, and switches
OFF automatically after 5sec.
009-004
#K_Disp MOT
K Color Disp. MOT turns ON, and switches
OFF automatically after 5sec.
009-005
#Y_DB DC
Y Color Developer Bias DC Component
Output
009-006
#M_DB DC
M Color Developer Bias DC Component
Output
009-007
#C_DB DC
C Color Developer Bias DC Component
Output
009-008
#K_DB DC
K Color Developer Bias DC Component
Output
009-009
#YM_DB AC
YM Color Developer Bias AC Component
Output
009-012
#CK_DB AC
CK Color Developer Bias AC Component
Output
009-013
Dev_CL
The clutch for driving K Color turns ON,
and switches OFF automatically after 5
sec.
009-014
Dev_MOT Normal-
Switches off automatically after 5 sec.
speed
009-016
Dev_MOT Half-
Switches off automatically after 5sec.
speed
009-017
Dev_MOT High-
Switches off automatically after 5sec.
speed
009-018
Dev bias AC
Switch on before starting BCR DC for each
enable
color.
009-026
#Y_BCR DC
High voltage output value of BCR DC_Y.
ON = PWM
009-027
#M_BCR DC
High voltage output value of BCR DC_M.
ON = PWM
009-028
#C_BCR DC
High voltage output value of BCR DC_C.
ON = PWM
009-029
#K_BCR DC
High voltage output value of BCR DC_K.
ON = PWM
009-030
#Y_BCR AC
High voltage output value of BCR AC_Y.
ON = PWM
009-031
#M_BCR AC
High voltage output value of BCR AC_M
009-032
#C_BCR AC
High voltage output value of BCR AC_C
009-033
#K_BCR AC
High voltage output value of BCR AC_K
009-034
AGT MOT
Agitator MOT ON
009-035
CRUM PWR
Power ON for CRUM-YMCK
Initial issue
DC 3535/2240/1632
Conflicts
Code
Name
-
009-037
Dev DC chg (K)
009-038
BCR ACDC K CHG DEVE_AC_K changes at connector termi-
-
009-039
BCRAC Clock
-
009-040
ROS Shutter Close ROS Shutter: Rotates in Close direction
-
009-041
ROS Shutter Open ROS Shutter: Rotates in Open direction
-
009-042
#K_Erase Lamp
-
009-045
#YMC_Erase Lamp YMC ERASE LAMP lit.
009-051
2nd BTR Contact
-
-
009-052
2nd BTR Retract
-
009-053
De Tack Saw HV
009-054
1st BTR Contact
-
009-055
1st BTR Retract
009-016,-017
009-056
2nd BTR Select
009-076
Specular reflection
009-014, -017
LED
009-016, -017
009-077
Diffusion reflection
LED
009-078
ADC Sensor Shut-
ter Open
009-030
009-079
ADC Sensor Shut-
ter Close
009-031
009-080
ATC Sensor 5V ON 5V Power supply to ATC SNR.
010-001
OCT Motor (CW)
009-032
010-002
OCT Motor (CCW) Switches on reverse and switches off auto-
9-33
012-001
Main Drive Motor
009-026
On/Off
012-010
Rear Tamper Motor
009-027
Low Front On/Off
009-028
009-029
02/03
6-93
Table 2 Output Component Control Codes
Description
nals trailing.
Frequency signal common to BCR AC All
Colors.
(Brush: Contact direction).
(Brush: Retract direction). ON = H
K ERASE LAMP lit.
BTR2 Retract MOT. Switches off 800ms
after the Retract SNR detected the Contact
Position (High).
Switches off 60ms after the Retract SNR
detected the Retract Position (Low).
Turn on DTS HV.
Switches off 100ms after the Retract SNR
detected the Contact Position (High).
Switches off 100ms after the Retract SNR
detected the Retract Position (Low).
selects polarity of bias voltage
When the Specular Reflection LED of ADC
SNR turns ON and YMC density is
detected.
When the Diffusion Reflection LED of ADC
SNR turns ON and K density is detected.
Switches off automatically after 100msec.
Switches off automatically after 100msec.
Switches on forward and switches off auto-
matically at 150msec.
matically at 150msec.
Switches off automatically after 100pulses.
General Procedures and Information
Conflicts
009-041
009-040
-
-
-
-
-
-
-
-
009-079
009-078
-
010-002
010-001
012-071
012-011, 012-
012, 012-013,
012-014, 012-
015
dC330