REP 12.4 Finisher
Parts List on
PL 17.5
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Separate IIT and IOT.
2.
Remove the following parts:
a.
H Transport Assembly
(REP
12.1)
b.
Stacker Tray
(PL
17.1)
c.
Right Cover
(PL
17.1)
3.
Disconnect the Finisher power and signal cable.
It is recommended to have two people available to remove the Finisher. The Finisher Unit
weighs more than 16Kg.
When only one person is available, take extreme care to avoid lower back injury.
4.
Remove the Finisher from the Rack
1
Remove Thumb-
screws (2)
3
Lift to
Remove
Finisher
Figure 1 Removing Finisher from Rack
Repairs and Adjustments
REP 12.4
WARNING
CAUTION
(Figure
1).
2
Push Finisher
away from Rack
to disengage
Finisher
02/03
4-104
Initial issue
DC 3535/2240/1632