9-654 ADC Sensor
The machine logic detected an ADC Sensor operation failure.
Procedure
The machine is a DC3535.
Y
N
Check
ADJ
9.4. The fail judgement of the ADC Sensor is OK.
Y
N
There is +5VDC from P/J536-A13 on the I/F PWB
Y
N
Go to
Figure
1. Check the wires and connectors. If the check is OK, replace the
I/F PWB
(PL
9.1). If the problem continues replace the MCU PWB
Enter
dC330
[009-078] and press Start. The ADC Shutter Solenoid energized
1.3).
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
9.1). If the problem continues replace the MCU PWB
Enter
dC330
[009-078]. There is 0VDC from P/J536-A8 on the I/F PWB to GND.
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
9.1). If the problem continues replace the MCU PWB
Enter
dC330
[009-079]. The voltage from P/J536-A6 to GND changed to 0VDC
momentarily.
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
9.1). If the problem continues replace the MCU PWB
Check the wires and connectors. If the check is OK, replace the ADC Sensor
Assembly
(PL
1.3).
After checking that no failures are detected during normal operation, go to call closeout.
Check
ADJ
9.4. The fail judgement of the ADC Sensor is OK.
Y
N
There is +5VDC from P/J536-A11 on the I/F PWB
Y
N
Go to
Figure
2. Check the wires and connectors. If the check is OK, replace the I/F U
PWB
(PL
13.1).
Enter
dC330
[009-078] and press Start. The ADC Shutter Solenoid
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB. If the prob-
lem continues, replace the MCU PWB
Enter
dC330
[009-078] and press Start. There is 0VDC from P/J536-A6 on the I/F
PWB.
A
Status Indicator RAPs
9-654
(PL
9.1) to GND.
(PL
13.1).
(PL
(PL
13.1).
(PL
13.1).
(PL
13.1).
(PL
9.1) to GND.
(PL
1.3) energized.
(PL
13.1).
A
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
the problem continues, replace the MCU PWB
Enter
dC330
[009-079 and press Start. The voltage from P/J536-A4 to GND changed
to 0VDC momentarily.
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
the problem continues, replace the MCU PWB
Check the wires and connectors. If the check is OK, replace the ADC Sensor Assembly
(PL
1.3).
After checking that no failures are detected during normal operation, go to call closeout.