15-386 CCD AOC1

Automatic Offset Control (AOC) for CCD Channel 1 failed.
Initial Actions
Verify that the Platen Glass is installed correctly
Verify that NVM location 715-400 = 1
Procedure
Enter
dC330
[6-002] and press Start. The Exposure Lamp illuminates.
Y
N
Go to the
6-371
RAP.
The Exposure Lamp illumination is bright and steady.
Y
N
Go to
Figure 1
and check
P/J724
for an open or short circuit.
Verify that
P/J742
on the Lamp Ballast PWB and
If the wires and connectors are good, replace the Exposure Lamp
If the problem continues, replace the Lamp Ballast PWB
If the problem continues, replace the IIT/IPS PWB
Remove the Platen Glass
(REP
6.2). The white reference strip on frame under the Regis-
tration Gate is clean and undamaged.
Y
N
Clean the white reference strip.
Go to
Figure 2
and check the flat cables on the IIT/IPS PWB ( P/J721) and the CCD PWB (
J741) for damage. Reseat the flat cable.
If the problem continues, replace the Lens Kit
If the problem continues, replace the IIT/IPS PWB
Initial issue
DC 3535/2240/1632
(REP
6.2).
P/J724
on the IIT/IPS PWB are seated.
(PL
18.6).
(PL
18.6).
(PL
18.3).
(PL
18.4).
(PL
18.3).
Figure 1 15-386 RAP Circuit Diagram - Lamp Ballast
P/
Figure 2 15-386 RAP Circuit Diagram - CCD
02/03
2-313
Status Indicator RAPs
15-386