Adj 9.3 Trc Control/Toner Density Setup (Dc922); Adj 9.4 Adc Output Check (Dc934) - Xerox DocuColor 2240 Service Manual

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

ADJ 9.3 TRC Control/Toner Density Setup (dC922)

Purpose
To check the output of ATC Sensor and to determine if TC Control performed normally.
Allows manual adjustment of TC if control is not functioning.
Check
1.
Connect the PWS to the machine and enter Diagnostic Mode (refer to
Mode using the
PWS).
2.
Under the Adjustments tab, select Max Setup.
3.
Select the TRC Control tab.
4.
Load letter size paper (8.5 x 11 or A4) into Tray 1.
5.
Select the Start button. The machine will read the output of the ATC Sensor and display
the results in the row labeled ATC Mean Detected Value. If the routine is unable to read
the ATC Sensor correctly, this fact will be displayed in the row labeled ATC Sensor Fail
Determination.
6.
If the row labeled ATC Sensor Fail Determination displays OK for all colors, continue
with the check. If any color is not OK, go to the appropriate RAP
for magenta,
9-382
for cyan, or
9-383
this procedure.
7.
Compare the data in the row labeled ATC Mean Detected Value with the data in the row
labeled ATC Control Environment Correction Standard. If the measured value for any
color is more than 50 bits higher or lower than the target (correction standard) value, per-
form the Adjustment.
8.
If the Check is OK, proceed to
ADJ
Adjustment
The Tone Judge window in the upper right portion of the screen shows the result of the ATC
Sensor read. Perform the following steps to adjust the toner density.
1.
Select Run. The control logic will automatically tone up or tone down each color per the
display.
2.
When the tone up/down cycle is complete, select Start to re-run the check.
NOTE: It is not necessary to repeat the tone up/down procedure until the match is exact.
3.
Repeat steps 2 and 3 until the ATC Mean Detected Value is within 50 bits of the ATC
Control Environment Correction Standard for all colors.
4.
Proceed to
ADJ
9.4, ADC Output Check.
Initial issue
DC 3535/2240/1632
Entering Diagnostic
(9-380
for yellow,
for black) to fix the problem before continuing with
9.4, ADC Output Check.

ADJ 9.4 ADC Output Check (dC934)

Purpose
To check the following functions
ADC (2 gradation) patch for Potential Control on the IBT
ADC Sensor output
Laser Diode light output
Check
1.
Connect the PWS to the machine and enter Diagnostic Mode (refer to
Mode using the
PWS).
2.
Under the Adjustments tab, select Max Setup.
3.
Select the ADC AGC Setup tab.
4.
Select the Start button. The machine will read the output of the ADC Sensor, The Laser
Diode, and Developer bias, and display the results on the screen.
5.
Check for unsatisfactory results:
If a fault code is declared, go to the RAP for that code. Resolve the problem, then
repeat the Check.
9-381
If ADC Shutter Fail is NG go to the
noid circuits
If ADC Sensor Fail is NG go to the
02/03
4-165
Entering Diagnostic
9-654
RAP and troubleshoot the shutter sole-
9-654
RAP and troubleshoot the sensor circuits.
Repairs and Adjustments
ADJ 9.3, ADJ 9.4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 3535Docucolor 1632