4-363 K Drum Motor

Drum Motor K failure.
Initial Actions
Remove all Drum Cartridges.
Perform
REP
1.6.
Procedure
The machine is a DC3535.
Y
N
Enter
dC330
[004-006] and press Start. Drum Motor K energizes.
Y
N
Go to
Figure 1
of this procedure and measure voltage between I/F PWB P/J534-A12
(+) and GND (-). +5 VDC is measured.
Y
N
Go to
Figure 3
of the +5 VDC Wirenets and troubleshoot the problem.
Go to
Figure 1
of this procedure and measure voltage between I/F PWB P/J534-A15
(+) and GND (-). +24 VDC is measured.
Y
N
Go to
Figure 2
of the +24 VDC Wirenets and troubleshoot the problem.
Enter
dC330
[004-006] and press Start. Measure voltage between:
P/J534-A9 (+) and GND (-)
P/J534-A10 (+) and GND (-)
P/J534-A11 (+) and GND (-)
Less than +1 VDC is measured on P/J534-A9,A10 and A11.
Y
N
Check connection between MCU PWB and I/F PWB (P410).
If no problems are found, replace the MCU PWB
If the problem persists, replace the I/F PWB
Check for wire damage between
If no problems are found, replace the Drum Motor
Enter
dC330
[004-006] and press Start. Measure AC and DC voltage between P/J534-A8
(+) and GND (-).
NOTE: If you can measure frequency (Hz) with your meter, then you may check for 800 -
900 Hz on P/J534-A8.
Approximately +2.1V AC and DC is measured (800 - 900 Hz is measured).
Y
N
Check connection between MCU PWB and I/F PWB (P410).
If no problems are found, replace the MCU PWB
If the problem persists, replace the I/F PWB
Enter
dC330
[004-006] and press Start. Measure voltage between P/J534-A7 (+) and
GND (-). Less than +1 VDC is measured.
A
Status Indicator RAPs
4-363
(PL
13.1).
(PL
9.1).
P/J534
and P/J235.
(PL
1.1).
(PL
13.1).
(PL
9.1).
A
Y
N
Replace Drum Motor
(PL
1.1).
Check connection between MCU PWB and I/F PWB (P410).
If no problems are found, replace the MCU PWB
If the problem persists, replace the I/F PWB
Enter
dC330
[004-006] and press Start. Drum Motor K energizes.
Y
N
Go to
Figure 2
of this procedure and measure voltage between I/F PWB P/J534-A6 (+)
and GND (-). +5 VDC is measured.
Y
N
Go to
Figure 3
of the +5 VDC Wirenets and troubleshoot the problem.
Go to
Figure 2
of this procedure and measure voltage between I/F PWB P/J534-A9 (+)
and GND (-). +24 VDC is measured.
Y
N
Go to
Figure 2
of the +24 VDC Wirenets and troubleshoot the problem.
Enter
dC330
[004-006] and press Start. Measure voltage between:
P/J534
-A5 (+) and GND (-)
P/J534
-A4 (+) and GND (-)
P/J534-A3 (+) and GND (-)
Less than +1 VDC is measured on P/J534-A5,A4 and A3.
Y
N
Check connection between MCU PWB and I/F PWB (P410).
If no problems are found, replace the MCU PWB
If the problem persists, replace the I/F PWB
Check for wire damage between
If no problems are found, replace the Drum Motor
Enter
dC330
[004-006] and press Start. Measure AC and DC voltage between P/J534-A2 (+)
and GND (-).
NOTE: If you can measure frequency (Hz) with your meter, then you may check for 800 - 900
Hz on P/J534-A2.
Approximately +2.1V AC and DC is measured (800 - 900 Hz is measured).
Y
N
Check connection between MCU PWB and I/F PWB (P410).
If no problems are found, replace the MCU PWB
If the problem persists, replace the I/F PWB
Enter
dC330
[004-006] and press Start. Measure voltage between P/J534-A1 (+) and GND (-
). Less than +1 VDC is measured.
Y
N
Replace Drum Motor
(PL
1.1).
Check connection between MCU PWB and I/F PWB (P410).
02/03
2-66
(PL
13.1).
(PL
9.1).
(PL
13.1).
(PL
9.1).
P/J534
and P/J235.
(PL
1.1).
(PL
13.1).
(PL
9.1).
Initial issue