5-195 Document Size Mismatch
Different sized documents are detected in the NO MIX mode.
Initial Actions
This fault can be caused by the following:
•
Mixed size documents are fed without selecting that option on the UI.
•
There is too much curl in the documents being fed through the DADF.
•
The documents are improperly loaded.
•
The type of document being fed (coated paper, etc.)
Instruct the operator on proper DADF operation.
Procedure
Enter
dC330
[005-150] and select Start. Actuate the DADF Size Sensor 1 (Rear)
The display changes.
Y
N
The display indicates a constant High.
Y
N
Go to
Flag
1. Check the wire for a short circuit to GND. If the wire is good, replace
the Size Sensor 1 (Rear)
(PL
Go to
Flag 1
and
Flag
2. Check the wires for an open circuit. If the wires are good, replace
the Size Sensor 1 (Rear)
(PL
20.5). If the problem continues, replace the DADF Control
PWB
(PL
20.3).
Enter
dC330
[005-151] and press Start. Actuate DADF Size Sensor 2 (Front)
display changes.
Y
N
The display indicates a constant High.
Y
N
Go to
Flag
3. Check the wire for a short circuit to GND. If the wire is good, replace
the Size Sensor 1 (Rear)
(PL
Go to
Flag 3
and
Flag
4. Check the wires for an open circuit. If the wires are good, replace
the Size Sensor 2 (Front)
(PL
20.5). If the problem continues, replace the DADF Control
PWB (PL 20.3).
Open the Document Feed Assembly and block the Registration Sensor with a sheet of paper.
The display changes.
Y
N
Go to the
5-702
Registration Sensor RAP
Check the following:
•
Size Sensor for correct installation
•
Multiple feed due to retard malfunction
•
DADF document skew caused by misadjustments
•
Document meets specification
•
Different document size (mixed documents)
Initial issue
DC 3535/2240/1632
20.5).
(PL
20.5).
(REP
5.12).
(PL
20.5).
(ADJ
5.2)
(ADJ
5.3)
(ADJ
(PL
20.5).
Figure 1 5-195 RAP Circuit Diagram - Size Sensor 1 (Rear)
20.5). The
Figure 2 5-195 RAP Circuit Diagram - Size Sensor 2 (Front)
5.4).
02/03
2-85
Figure 3 DADF Control PWB
Status Indicator RAPs
5-195