ADJ 9.12 IIT Vertical/Horizontal Magnification
Purpose
To correct the horizontal (fast scan)/vertical (slow scan) magnification ratio for a 100% copy.
Check
Perform this procedure only if absolutely required; changing IIT magnification may adversely
affect resolution due to ASIC shift, and may cause a color shift.
NOTE: Before performing this procedure, make sure that the IOT horizontal/vertical magnifica-
tion ratios are correct.
1.
Place the Geometric Test Pattern on the Platen Glass and make a copy using the follow-
ing copy mode settings:
•
Copy Mode: Black
•
Document Type: Text/Photo
•
Paper: 11 x17 in. or A3
•
Magnification: 100%
•
No. of Copies: 2
2.
Check the 2nd copy for the following:
3.
Check horizontal magnification
(Figure
Measure the 200mm line running from near LE1 to near LE3. If the dimension is not
200mm ±1mm, perform the Adjustment.
Initial issue
DC 3535/2240/1632
CAUTION
1):
Figure 1 Checking Horizontal Magnification
02/03
4-175
Lead Edge
200mm
+/-1mm
Repairs and Adjustments
ADJ 9.12