IQ8 Color-to-Color Misregistration RAP
Initial Actions
Adjust the color registration
(ADJ
9.6). If the problem remains, continue with this procedure.
Check the fault history for 4-640, 4-641, or
Procedure
The problem is an incorrect horizontal and/or vertical positioning of one or more of the
four colors.
Y
N
Check that the ROS is securely mounted and that the ROS window is not dirty or dam-
aged. If the problem persists, replace the ROS
Check the mounting of the Developer Housing for the affected color. Ensure that it is installed
correctly and that it is free from damage. Repair or replace as required
Initial issue
DC 3535/2240/1632
4-642
faults.
(PL
3.1).
(PL
6.2).
02/03
3-11
Image Quality
IQ8