3-327 IIT-ESS Communication Failure 8

Controller received check code error (over-run error in IISS).
Procedure
Switch the power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors (P/J Loca-
tions,
Figure
30). If the check is OK, replace the IIT/IPS PWB
Initial issue
DC 3535/2240/1632
3-328 IIT-ESS Communication Failure 9
Controller received check code error (transmission aborted after header received).
Procedure
Switch the power off then on. The problem continues.
Y
Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors (P/J Loca-
(PL
18.3).
tions,
02/03
2-21
N
Return to Service Call Procedures.
Figure
30). If the check is OK, replace the IIT/IPS PWB
(PL
18.3).