3-343 IOT-ESS Communication Failure 4

Controller received check code error (wrong message packet length in sent packet).
Procedure
Switch the power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Reinstall the software. If the problem continues, check the MCU PWB connectors (P/J Loca-
tions,
Figure
15). DC 3535 only: Replace the VSEL PWB
replace the MCU PWB
(PL
13.1).
Status Indicator RAPs
3-343, 3-345
3-345 IOT-ESS Communication Failure 5
Controller received check code error (sent packet checksum error).
Procedure
Switch the power off then on. The problem continues.
Y
Reinstall the software. If the problem continues, check the MCU PWB connectors (P/J Loca-
(PL
13.1). If the problem persists,
tions,
replace the MCU PWB
02/03
2-28
N
Return to Service Call Procedures.
Figure
15). DC 3535 only: Replace the VSEL PWB
(PL
13.1).
(PL
13.1). If the problem persists,