9-660 Environment Sensor Temperature
An incorrect value was detected by the Environment Sensor (Temperature).
Procedure
Disconnect P/J255. There is 1 Ohm or less measured between P255-3 and P255-4 on the
Environment Sensor
(Figure
1).
9-661 Environment Sensor Humidity
An incorrect value was detected by the Environment Sensor (Humidity).
Procedure
There is +0.4VDC to +17VDC from P/J536-B3 on the I/F PWB to GND
Y
N
There is +5VDC from P/J536-B4 on the I/F PWB to GND.
A
Status Indicator RAPs
9-660, 9-661
Y
N
Replace the Environment Sensor
Replace the I/F PWB
Figure 1 9-660 Rap Circuit Diagram - Environment Sensor
A
Y
Go to
(Figure
1).
Environment Sensor
Replace the I/F PWB
Figure 1 9-661 Rap Circuit Diagram - Environment Sensor
02/03