Xerox DocuColor 2240 Service Manual page 935

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

Chain-Link
Name
752-081
ATC Average [Y]
752-082
ATC Average [M]
752-083
ATC Average [C]
752-084
ATC Average [K]
752-089
ATC Fluctuation [Y]
752-090
ATC Fluctuation [M]
752-091
ATC Fluctuation [C]
752-092
ATC Fluctuation [K]
752-109
Number of Continuous ATC Fails [Y]
752-110
Number of Continuous ATC Fails [M]
752-111
Number of Continuous ATC Fails [C]
752-112
Number of Continuous ATC Fails [K]
752-114
Warn ATC Max & min. [Y]
752-115
Warn ATC Max & min. [M]
752-116
Warn ATC Max & min. [C]
752-117
Warn ATC Max & min. [K]
752-118
Warn ATC Fluctuation Max & min. [Y]
752-119
Warn ATC Fluctuation Max & min. [M]
752-120
Warn ATC Fluctuation Max & min. [C]
752-121
Warn ATC Fluctuation Max & min. [K]
752-122
Fail ATC Patch [Y]
752-123
Fail ATC Sensor [M]
752-124
Fail ATC Sensor [C]
752-125
Fail ATC Sensor [K]
752-130
Set ATC Control Nominal Value [0] [Y]
752-131
Set ATC Control Nominal Value [0] [M] *
752-132
Set ATC Control Nominal Value [0] [C]
752-133
Set ATC Control Nominal Value [0] [K]
752-134
Set ATC Control Nominal Value [1] [Y]
752-135
Set ATC Control Nominal Value [1] [M] *
752-136
Set ATC Control Nominal Value [1] [C]
752-137
Set ATC Control Nominal Value [1] [K]
752-138
Set ATC Control Nominal Value [2] [K]
Initial issue
DC 3535/2240/1632
Table 1 Chain 752
Default
Range
Description
0
0~1023
ATC Average detected value after sensor sensitivity correction
0
0~1023
ATC Average detected value after sensor sensitivity correction
0
0~1023
ATC Average detected value after sensor sensitivity correction
0
0~1023
ATC Average detected value after sensor sensitivity correction
0
0~1023
ATC Fluctuation Range detected value after sensor sensitivity correction
0
0~1023
ATC Fluctuation Range detected value after sensor sensitivity correction
0
0~1023
ATC Fluctuation Range detected value after sensor sensitivity correction
0
0~1023
ATC Fluctuation Range detected value after sensor sensitivity correction
0
0~255
No. of Continuous ATC Fails
0
0~255
No. of Continuous ATC Fails
0
0~255
No. of Continuous ATC Fails
0
0~255
No. of Continuous ATC Fails
0
0~2
ATC Upper and Lower Limits Warning (0=Normal, 1=ATC Output low HiTC, 2=ATC Output high LowTC)
0
0~2
ATC Upper and Lower Limits Warning (0=Normal, 1=ATC Output low HiTC, 2=ATC Output high LowTC)
0
0~2
ATC Upper and Lower Limits Warning (0=Normal, 1=ATC Output low HiTC, 2=ATC Output high LowTC)
0
0~2
ATC Upper and Lower Limits Warning (0=Normal, 1=ATC Output low HiTC, 2=ATC Output high LowTC)
0
0~2
ATC Fluctuation Range Lower Limit Warning (0=Normal, 1=To little fluctuation)
0
0~2
ATC Fluctuation Range Lower Limit Warning (0=Normal, 1=To little fluctuation)
0
0~2
ATC Fluctuation Range Lower Limit Warning (0=Normal, 1=To little fluctuation)
0
0~2
ATC Fluctuation Range Lower Limit Warning (0=Normal, 1=To little fluctuation)
0
0~1
ATC Sensor Fail
0
0~1
ATC Sensor Fail
0
0~1
ATC Sensor Fail
0
0~1
ATC Sensor Fail
*
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup
*default=602 for DC2240/1632; 595 for DC3535
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup
*default=602 for DC2240/1632; 595 for DC3535
*
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup
*default=602 for DC2240/1632; 595 for DC3535
*
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup
*default=602 for DC2240/1632; 595 for DC3535
*
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup
*default=642 for DC2240/1632; 645 for DC3535
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup
*default=642 for DC2240/1632; 645 for DC3535
*
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup
*default=642 for DC2240/1632; 645 for DC3535
*
0~1023
[ATC Control Nominal Value before environment/deterioration correction as center setup
*default=652 for DC2240/1632; 645 for DC3535
*
0~1023
ATC Control Nominal Value before environment/deterioration correction as center setup