APPENDIX 1.2 Minor errors

Error
Erroneous
code
data
Home position return start
of the proximity dog,
count, data set, dog
21
cradle, stopper, limit
switch combined and
scale home position
signal detection type
Home position return start
22
of the proximity dog,
count, dog cradle,
stopper, limit switch
combined and scale home
23
position signal detection
type
Home
position
Home position return start
return data
24
of the count type
Home position return start
of the count, proximity
dog, dog cradle, stopper,
25
limit switch combined and
scale home position
signal detection type
Home position return start
26
of the stopper type
Home position return start
27
of the usable retry
function
Parameter
40
Interpolation control start
block
These errors are detected in the sequence program or servo program, and the error
codes of 1 to 999 are used.
Minor errors include the setting data errors, starting errors, positioning control errors
and current value/speed/target position change errors, synchronous control output axis
errors, synchronous control input axis errors and system errors.
(1) Setting data errors (1 to 99)
These errors occur when the data set in the parameters for positioning control is
not correct.
The error codes, causes, processing, and corrective actions are shown in Table
1.3.
Table 1.3 Setting data error (1 to 99) list
Check timing
The home position address is
outside the range of 0 to
35999999 ( 10
degree axis.
The home position return speed
is outside the range of 1 to
speed limit value.
The creep speed is outside the
range of 1 to home position
return speed.
The travel value after the
proximity dog ON is outside the
range of 0 to (2
The parameter block No. is
outside the range of 1 to 64.
Torque limit value at the creep
speed is outside the range of 1
to 1000[%].
Dwell time at the home position
return is outside the range of 0
to 5000[ms].
The interpolation control unit of
the parameter block is different
from the control unit of the fixed
parameters.
Error cause
processing
–5
[degree]) with
Home position
return is not
started.
31
-1) ( unit).
Control with the
control unit of
the fixed
parameters.
APP - 9
Error
Corrective action
Set the home position address
within the setting range using
MT Developer2.
Set the home position return speed
or less to the speed limit value
using MT Developer2.
Set the creep speed below to the
home position return speed or less
using MT Developer2.
Set the travel value after the
proximity dog ON within the setting
range using MT Developer2.
Set the parameter block No. within
the setting range using MT
Developer2.
Set the torque limit value at the
creep speed within the setting
range using MT Developer2.
Set the dwell time at the home
position return retry within the
setting range using MT Developer2.
Set the same control unit of the
fixed parameters and servo
parameters.