7 SYNCHRONOUS CONTROL
(3) [Pr.424] Auxiliary shaft clutch ON address (D15032+150n,
D15033+150n)
Set the clutch ON address when address mode is configured for the ON control
mode of the auxiliary shaft clutch.
When the reference address is the current value per cycle after auxiliary shaft
gear, the setting address is converted for control within the range from 0 to (Cam
axis length per cycle - 1).
Example) Cam axis length per cycle: 20000[PLS]
The ON address is controlled as 19000[PLS] when the setting value is
-1000.
(4) [Pr.425] Travel value before auxiliary shaft clutch ON
(D15034+150n, D15035+150n)
Set the travel value for the reference address with a signed numbers for the
distance between the clutch ON condition completing and the clutch closing.
• 1 to 2147483647 (Positive value)
• 0
• -2147483648 to -1(Negative value) : Used when the reference address is
Clutch ON condition is completed
(Example: [Rq.403] Auxiliary shaft clutch
command (M11684+10n) ON)
[St.423] Auxiliary shaft clutch ON/OFF
status (M10562+10n)
Auxiliary shaft current value or
[Md.402] Current value per cycle after
auxiliary shaft gear
(D13604+30n, D13605+30n)
Travel value after clutch
(5) [Pr.426] Auxiliary shaft clutch OFF address (D15036+150n,
D15037+150n)
Set the clutch OFF address when address mode is configured for the OFF
control mode of the auxiliary shaft clutch.
When the reference address is the current value per cycle after auxiliary shaft
gear, the setting address is converted for control within the range from 0 to (Cam
axis length per cycle - 1).
Example) Cam axis length per cycle: 20000[PLS]
The OFF address is controlled as 60[PLS] when the setting value is
40060.
: Used when the reference address is
increasing in direction.
: No movement (The clutch is immediately
turned ON with the clutch ON condition
completing.)
decreasing in direction.
ON
OFF
OFF
7 - 23
ON
[Pr.425] Travel value before auxiliary shaft
clutch ON (D15034+150n, D15035+150n)
(Positive value)
t
t