Cam Data Operation By Motion Sfc Program - Mitsubishi Electric Q173DSCPU Programming Manual

Motion controller q series
Hide thumbs Also See for Q173DSCPU:
Table of Contents

Advertisement

6 CAM FUNCTION

6.2.2 Cam data operation by Motion SFC program

Cam data read/write operation and cam auto-generation can be executed with the
synchronous control dedicated function of Motion SFC program.
Refer to the "Q173D(S)CPU/Q172D(S)CPU Motion controller (SV13/SV22)
Programming Manual (Motion SFC)" for details.
Classification
Symbol
CAMRD
CAMWR
Synchronous
control dedicated
function
CAMWR2
CAMMK
Instruction
This is used to read cam data.
The upper amount of data for each operation is
4096 points (2 words are used per point.) with the
Cam data read
stroke ratio data format, and 2048 points (4 words
are used per point.) with the coordinate data format.
If the read is not completed in one time, the
operation should be separated in multiple times.
This is used to write cam data.
The upper amount of data for each operation is
4096 points (2 words are used per point.) with the
Cam data write
stroke ratio data format, and 2048 points (4 words
are used per point.) with the coordinate data format.
If the write is not completed in one time, the
operation should be separated in multiple times.
This is used to write cam data to cam open area.
The upper amount of data for each operation is
4096 points (2 words are used per point.) with the
Cam data write
stroke ratio data format, and 2048 points (4 words
(Cam open area)
are used per point.) with the coordinate data format.
f the write is not completed in one time, the
operation should be separated in multiple times.
This function is used to automatically generate cam
data for specific purposes by setting data for auto-
generation.
Data for auto-generation is stored in the cam
storage area, and the cam data generated by the
Cam auto-generation
cam auto-generation function is generated in the
function
cam open area.
It is possible to generate up to 1Mbyte including the
regular cam data.
(Example): 256 cam data (with the stroke ratio
6 - 10
Description
format, resolution is 1024) can be
automatically generated.