Table 3-18 Addparty Command Parameters - Cisco MGX 8850 (PXM1E/PXM45) Configuration Manual

Multiservice switch
Table of Contents

Advertisement

General PXM1E Configuration Procedures

Table 3-18 addparty Command Parameters

Parameter
port
vpi
vci
epref
party
The following example adds a party to master endpoint 7:2.11:11, which uses VPI 100 and VCI 100:
PXM1E_SJ.8.PXM.a > addparty 7:2.11:11 100 100 1 -party
4700918100000000001A533377000001073B0C00.101.101
To verify that the party was added properly, enter the dspparty command as follows:
Step 3
mgx8830a.1.PXM.a > dspparty <port> <vpi> <vci> <epref>
The dspparty command parameters identify the root endpoint and are the same parameters you specified
with the addparty command
display:
XM1E_SJ.8.PXM.a > dspparty 7:2.11:11 100 100 1
Port
----------------------------------------------------------------------------
Local
Remote 7:2.12:12
Endpoint Reference: 1
Last Fail Cause: No Fail
Step 4
To view all the configured parties, enter the dspparties command as follows:
PXM1E_SJ.8.PXM.a > dspparties
Local Port
-------------------------------+-----------------------+---------+------+-------
7:2.11:11
Local
Remote Addr: 47.00918100000000001a533377.000001073b0c.00
Repeat Steps 4 and 5 to add more parties, one at a time, to the root you created in Step 2.
Step 5
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
3-82
Description
Root endpoint port identifier, in the format
[shelf.]slot[:subslot].port[:subport]. To display a list of the available ports
using port numbers in the correct format, enter the dsppnports command.
Root endpoint VPI. Enter the VPI specified when the root endpoint was
created. To display a list of connections that includes the VPI and VCI for
each connection, enter the dspcons command.
Root endpoint VCI. Enter the VPI specified when the root endpoint was
created. To display a list of connections that includes the VPI and VCI for
each connection, enter the dspcons command.
Endpoint reference. The range is 1 to 32767.
PartyNSAP.vpi.vci To obtain a slave/party's NSAP, see the
NSAP for a Party"
(Table
Vpi Vci
7:2.11:11
100.100
Address: 47.00918100000000001a533377.000001073b0b.00
Node name: PXM1E_SJ
101.101
Address: 47.00918100000000001a533377.000001073b0c.00
Node name: PXM1E_SJ
Vpi.Vci
Epref
100 100
1
Addr: 47.00918100000000001a533377.000001073b0b.00
Chapter 3
section that follows.
3-18). The following example shows the dspparty command
Owner
State
MASTER
OK
PARTY
OK
Attempts: 0
Remote Port
Vpi.Vci
7:2.12:12
101 101
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Provisioning PXM1E Communication Links
"Obtaining the
Persistency
Persistent
Non-Persistent
State
Owner
Persistency
OK
MASTER
Persistent

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgx 8950Mgx 8830Mgx 8880