Cisco MGX 8850 (PXM1E/PXM45) Configuration Manual page 238

Multiservice switch
Table of Contents

Advertisement

Setting Up SRM Lines
If you are configuring a Cisco MGX 8850 (PXM1E/PXM45) switch, replace X with 15 for an SRME in
the upper bay, or 31 for an SRME in the lower bay. If you are configuring a Cisco MGX 8830 switch,
replace X with 7. SRME provides one line, so the line number is always one as shown in the following
example:
PXM1E_SJ.8.PXM.a > dspln -sonet 31.1
Line Number
Admin Status
Loopback
Frame Scrambling
Xmt Clock source
Line Type
Medium Type(SONET/SDH) : SONET
Medium Time Elapsed
Medium Valid Intervals : 0
Medium Line Type
Step 3
To configure a SONET or SDH line, enter the cnfln command as follows:
mgx8830b.1.PXM.a > cnfln -sonet <X.1> -slt <LineType> -clk <clockSource>
-sfs <FrameScramble> -rdiv <RDI-V Type> -rdip <RDI-P Type> -tt <Tributary Type> -tm
<TributaryMappingType> -tf <TributaryFramingType> -st <SignallingTranportMode> -tg
<TributaryGroupingType>
Remember that you cannot configure a line until you have brought it up as described in the previous
section,
SDH lines.
Table 5-1
Parameter
X.1
-slt
-clk
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
5-6
: 31.1
: Up
: NoLoop
: Enable
: localTiming
: sonetSts3
: 508
: ShortSMF
"Bringing Up
Lines."
Table 5-1
Parameters for SONET Line Configuration
Description
Replace X with 15 if you are configuring an SRM in the upper
bay, or replace it with 31 if you are configuring an SRM in
the lower bay.
The number 1 represents the one and only line on an SRME
card.
Optical line type. Replace < LineType> with 1, to specify
SONET, or replace < LineType> with 2 to specify SDH.
The -clk option selects the primary source timing for
transmitting messages over the line. Replace <clockSource>
with 1 to use the clock signal received over this line from a
remote node, or specify 2 to use the local timing defined for
the local switch.
On SRME/B cards, when the selected primary source
Note
timing is not operating properly, the SRME/B will
use the other timing option. For example, if you select
option 1 as the primary source, option 2 will be the
secondary source and will be used when the option 1
timing fails.
For information on defining the clock source for the local
switch, see the
Network Using
Operating Procedures."
Chapter 5
APS enabled
RDI-V Type
RDI-P Type
VT Type
VT Mapping Type
VT Framing Type
VT Signalling Mode
VT Grouping Type
lists the parameter descriptions for configuring SONET and
"Managing the Time of Day Across the
SNTP" section in
Chapter 9, "Switch
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Preparing SRM Cards for Communications
: Disable
: one bit
: one bit
: vt15/vc11
: asynchronous
: N/A
: N/A
: N/A
-
lpb <loopback>

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgx 8950Mgx 8830Mgx 8880

Table of Contents