Error Messages At The System Boot - Hitachi Compute Blade 500 Series User Manual

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Status
Rebuild
Unconfigured Good This is not used for a virtual drive
Unconfigured Bad
Missing

Error messages at the system boot

Here is a list of messages for MegaRAID WebBIOS displayed at system
startup.
A discovery error has occurred.
Power-cycle the system and all the
enclosures attached to this
system.
All of the disks from your previous
configuration are gone. If this is an
unexpected message, then power
off your system and check your
cables to ensure all disks are
present.
Press any key to continue or press
C to load the configuration utility
The physical drive is separated from the virtual drive due to a
failure.
Rebuilding is underway.
A fault has occurred.
The unrecognizable physical drive is restored to recognizable.
A fault has occurred.
A "normal" physical drive has been removed.
Message
SAS 3004 iMR ROMB Configuration Utility
Hitachi Compute Blade 500 Series EFI User's Guide
Description
Description
Cause:
The disk array controller was not recognized.
Action:
If this message appeared, contact your reseller
or call maintenance personnel.
In addition, if this message appeared, the
system startup cannot continue.
Cause:
No logical drives are recognized.
Action 1:
a
Enter a character, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Action 2:
a
Press the C key, and then press the Enter
.
key.
b
The LSI MegaRAID <HITACHI SAS 3004
.
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message is displayed even though the
physical drive is properly mounted, contact your
reseller or call maintenance personnel.
5-53